SIL3, CL3 Safety Light Curtains :
20 Products FoundFind a huge range of SIL3, CL3 Safety Light Curtains at element14 Philippines. We stock a wide range of Safety Light Curtains, such as SIL3, SIL3, SIL CL3, SIL1 & SIL3, CL3 Safety Light Curtains from the worlds top manufacturers including: Banner Engineering
All Filters
(1 Applied)
Expand Filters
Manufacturer
(20)
Safety Integrity Level
=SIL3, CL3
1
(20)
(16)
(156)
(20)
(29)
Performance Level
(20)
Safety Curtain Category
(20)
Protection Height
(2)
(2)
(2)
(2)
(3)
(2)
(3)
(1)
Sensing Range Max
(20)
IP Rating
(20)
Approvals / Standards
(11)
(9)
Beam Spacing
(9)
(11)
Control Output Type
(9)
Supply Voltage Max
(20)
Packaging
(20)
| Compare | Manufacturer Part No | Order Code | Manufacturer / Description | Availability | Price For | Price | Quantity | Performance Level | Safety Curtain Category | Safety Integrity Level | Protection Height | Sensing Range Max | IP Rating | Approvals / Standards | Beam Spacing | Control Output Type | Supply Voltage Max | Product Range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | 1+Php98,702.300 | PL e | Level 4 | SIL3, CL3 | 1.2m | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php88,954.400 | PL e | Level 4 | SIL3, CL3 | 900mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php112,027.500 | PL e | Level 4 | SIL3, CL3 | 1.2m | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php78,490.300 | PL e | Level 4 | SIL3, CL3 | 900mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php85,191.400 | PL e | Level 4 | SIL3, CL3 | 750mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php113,564.800 | PL e | Level 4 | SIL3, CL3 | 1.35m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php46,950.900 | PL e | Level 4 | SIL3, CL3 | 450mm | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php58,042.200 | PL e | Level 4 | SIL3, CL3 | 600mm | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php110,570.500 | PL e | Level 4 | SIL3, CL3 | 1.05m | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php72,467.400 | PL e | Level 4 | SIL3, CL3 | 600mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php146,838.200 | PL e | Level 4 | SIL3, CL3 | 1.8m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php37,076.100 | PL e | Level 4 | SIL3, CL3 | 300mm | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php59,810.500 | PL e | Level 4 | SIL3, CL3 | 450mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php91,315.100 | PL e | Level 4 | SIL3, CL3 | 1.05m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php80,224.300 | PL e | Level 4 | SIL3, CL3 | 900mm | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php69,133.000 | PL e | Level 4 | SIL3, CL3 | 750mm | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php124,656.500 | PL e | Level 4 | SIL3, CL3 | 1.5m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php47,086.100 | PL e | Level 4 | SIL3, CL3 | 300mm | 12m | IP65 | CE, cULus | 14mm | PNP, OSSD | 24VDC | S4B Series | ||||||
Each | 1+Php102,474.400 | PL e | Level 4 | SIL3, CL3 | 1.2m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||
Each | 1+Php135,746.900 | PL e | Level 4 | SIL3, CL3 | 1.65m | 12m | IP65 | CE | 30mm | - | 24VDC | S4B Series | ||||||



